Mon - Sat 9.00 AM - 10.00 PM
Goregaon west , Mumbai
+91 99309 72610

COLD ROOM PUF PANEL

Sr. No. Parameters Description
1 Average PUF Density 40 ± 2 Kg/ cu.mtr/ m³
2 PUF Blowing Agent 141B (CFC free)
3 Insulation Material Polyurethane foam
4 Temperature range +90°C to -60°C
5 Penal Type Discontinuous type with cam lock
6 M.O.C. Of Cam Locks Cam locks body material HIPS and male latch is made of nylon Glass field with GI sheet reinforcement.
Cam-lock panel joints easy assembly and leakage resistant, panel-to-panel joints.
7 Type Of Panel Joints Tongue & Groove Joint with Cam lock and all side rubber gaskets
8 Corner Panel Available 12” X 12” X 162”(Maximum Length)
9 Length of wall & ceiling panel 2032 mm to 12000 mm 80” to 472.5” inch
10 Ceiling Suspension items with specs MS bolt with thermal breaking cap
PVC Round Plate 6 mm thickness x 90 mm diameter
Aluminium/MS washer plate for load distribution
Anchor bolt (MS) hanging bolt with 40 mm washer 2.0 mm thickness
Sealing to panel MS road Clamp with an insulated crown
11 Closed cell content 90 to 95%
12 Vapour Permeability 5.5mg/PASM
13 Water Absorption Less than 2%
14 Fire Resistance FR Grade B2 (Fire Resistance Grade)
15 Compressive Strength at 10% Deformation 0.21 N/ sq.mm (For PUF only)
16 Tensile Strength 0.58 N/ sq.mm (For PUF only)
17 Adhesive Strength(Foam to Sheet) 2.9kg/sq.mtr
18 Panel Facing Availability With Rib or plain on Demand (Ribs are provided for more strength)
19 Wall & Celling Panel Facing material Pre Painted Galvanised sheet, Thickness 0.50mm
Plain Galvanised sheet, Thickness 0.50mm
S.S. sheet, Grade 316, 0.50mm finish 2B/ 0.6mm mate No.4
S.S sheet, Grade 304, 0.50mm finish 2B/ 0.6mm mate No.4
20 Floor Panel Facing Material • PUF Panel with both side tarfelt sheet.
• PUF Panel with both side 0.5mm GIPP sheet.
• PUF Panel with outside GIPP sheet, inside 9 mm thick marine ply with 2 mm thick Aluminium Chequered Plate
21 Specification for Colour Coating A. RAL No.: 9002/9003 or it’s nearest
B. Indian Standard Code
Colour Coating: IS 14246 Galvanizing : IS 277 Base Metal : IS 513
C. Organic Coating: Type RMP (Polyester)
D. Zinc Coating : 120 GSM
E. Top Primer (Thickness in micron ‘μ’): 5 +/- 1 μ
F. Top Coat (Thickness in micron ‘μ’): 20 +/- 1 μ
G. Back Primer (Thickness in micron ‘μ’): 4 +/- 1 μ
H. Back Coat (Thickness in micron ‘μ’): 4 +/- 1 μ
I. Guard Film (Thickness in micron ‘μ’):40 +/- 3 μ
J. Salt Spray Test /Humidity Test: 750 hrs. /1000 hrs.